+86 15290525687 sales@jianyuncable.com
Low Voltage Power Cable
Low Voltage Power Cable

Low voltage power cables are used to transmit electrical power at voltages typically up to 1,000 volts (1 kV). These cables are widely used in residential, commercial, and industrial settings for a variety of applications, including power distribution, lighting, and control systems.

Home / Product / Low Voltage Power Cable / 0.6/1KV CU/XLPE/SWA/PVC Cable

0.6/1KV CU/XLPE/SWA/PVC Cable

0.6/1KV CU/XLPE/SWA/PVC Cable

The outer PVC (Polyvinyl Chloride) sheath offers additional protection against moisture, chemicals, and UV exposure, ensuring long-term durability and safety. This type of cable is ideal for use in underground, outdoor, and industrial environments where mechanical protection and reliability are crucial.

  • Details

0.6/1KV CU/XLPE/SWA/PVC Cable Introduction

Construction

Voltage Rating: 600/1000 Volts

Conductor: soft annealed copper

Insulation: Cross Linked Poly Ethylene (XLPE)

Armour: Steel Wire Armoured

Oversheath: PVC

Application:These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Single core( aluminum wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
1x4 2.3 1 1 0.8 1.8 11.5
1x6 2.8 1 1 0.8 1.8 12
1x10 3.6 1 1 0.8 1.8 12.8
1x16 4.5 1 1 0.8 1.8 13.7
1x25 5.6 1.2 1 0.8 1.8 15.2
1x35 6.7 1.2 1 1.25 1.8 17.2
1x50 8 1.4 1 1.25 1.8 18.9
1x70 9.4 1.4 1 1.25 1.8 20.3
1x95 11 1.6 1 1.6 1.8 23
1x120 12.4 1.6 1 1.6 1.8 24.4
1x150 13.8 1.8 1 1.6 1.8 26.2
1x185 15.3 2 1 1.6 1.9 28.2
1x240 17.5 2.2 1 1.6 1.9 31
1x300 19.5 2.4 1 2 2.1 34.4
1x400 22.6 2.6 1.2 2 2.2 38.6
1x500 25.2 2.8 1.2 2 2.3 41.8
1x630 28.3 2.8 1.2 2.5 2.4 46.2

Two cores(Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
2x2.5 1.8 0.8 1 0.8 1.8 14
2x4 2.3 1 1 1.25 1.8 16.7
2x6 2.8 1 1 1.25 1.8 17.7
2x10 3.6 1 1 1.25 1.8 19.3
2x16 4.5 1 1 1.25 1.8 21.1
2x25 5.6 1.2 1 1.6 1.8 24.8
2x35 6.7 1.2 1 1.6 1.8 27
2x50 8 1.4 1 1.6 1.9 30.7
2x70 9.4 1.4 1 2 2.1 34.5
2x95 11 1.6 1.2 2 2.2 39.2
2x120 12.4 1.6 1.2 2 2.3 42.2
2x150 13.8 1.8 1.2 2.5 2.5 47.2
2x185 15.3 2 1.4 2.5 2.6 51.6
2x240 17.5 2.2 1.4 2.5 2.8 57.2
2x300 19.5 2.4 1.6 2.5 3 62.8
2x400 22.6 2.6 1.6 2.5 3.2 70.3

Three cores(Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
3x2.5 1.8 0.8 1 0.8 1.8 14.5
3x4 2.3 1 1 1.25 1.8 17.4
3x6 2.8 1 1 1.25 1.8 18.4
3x10 3.6 1 1 1.25 1.8 20.2
3x16 4.5 1 1 1.6 1.8 22.8
3x25 5.6 1.2 1 1.6 1.8 26
3x35 6.7 1.2 1 1.6 1.9 28.5
3x50 8 1.4 1 2 2 33.3
3x70 9.4 1.4 1.2 2 2.1 37
3x95 11 1.6 1.2 2 2.3 41.6
3x120 12.4 1.6 1.2 2.5 2.4 45.9
3x150 13.8 1.8 1.4 2.5 2.6 50.4
3x185 15.3 2 1.4 2.5 2.7 54.8
3x240 17.5 2.2 1.5 2.5 2.9 61.2
3x300 19.5 2.4 1.6 2.5 3.1 66.8
3x400 22.6 2.8 1.6 3.15 3.4 76.7
3x500 25.2 2.8 1.8 3.15 3.7 83.6

3+1cores(Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm mm mm
3x10/6 3.6 2.8 1 1 1 1.25 1.8 21.9
3x16/10 4.5 3.6 1 1 1 1.6 1.8 24.2
3x25/16 5.6 4.5 1.2 1 1 1.6 1.8 27.9
3x35/16 6.7 4.5 1.2 1 1 1.6 1.9 30.8
3x50/25 8 5.6 1.4 1.2 1 2 2 36.4
3x70/35 9.4 6.7 1.4 1.2 1.2 2 2.1 40.1
3x95/50 11 8 1.6 1.4 1.2 2.5 2.3 46.3
3x120/70 12.4 9.4 1.6 1.4 1.4 2.5 2.4 50.3
3x150/70 13.8 9.4 1.8 1.4 1.4 2.5 2.6 55
3x185/95 15.3 11 2 1.6 1.4 2.5 2.7 60.3
3x240/120 17.5 12.4 2.2 1.6 1.6 2.5 2.9 67
3x300/150 19.5 13.8 2.4 1.8 1.6 3.15 3.1 74.6
3x400/185 22.6 15.3 2.6 2 1.8 3.15 3.4 84.1
3x500/240 25.2 17.5 2.8 2.2 2 3.15 3.7 91.8

Four cores(Galvanized steel wire armoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation thickness Nominal Inner Covering thickness Nominal Steel Wire dia. Nominal Sheath thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm mm mm
4x4 2.3 1 1 1.25 1.8 18.5
4x6 2.8 1 1 1.25 1.8 19.7
4x10 3.6 1 1 1.25 1.8 22.3
4x16 4.5 1 1 1.6 1.8 24.5
4x25 5.6 1.2 1 1.6 1.9 28.2
4x35 6.7 1.2 1 1.6 2 31.1
4x50 8 1.4 1 2 2.1 36.7
4x70 9.4 1.4 1.2 2 2.3 40.4
4x95 11 1.6 1.2 2.5 2.5 46.6
4x120 12.4 1.6 1.4 2.5 2.6 50.6
4x150 13.8 1.8 1.4 2.5 2.7 55.3
4x185 15.3 2 1.4 2.5 2.9 60.6
4x240 17.5 2.2 1.6 2.5 3.1 67.3
4x300 19.5 2.4 1.6 3.15 3.4 74.9
4x400 22.6 2.6 1.8 3.15 3.7 84.4
4x500 25.2 2.8 2 3.15 3.9 92.1