Home / Product / Low Voltage Power Cable / Low Voltage Aluminum YJLV Cable (16-35mm, XLPE/PVC) for Commercial Buildings
16mm 25mm 35mm Low Voltage Aluminum Conductor XLPE Insulation PVC Sheath YJLV Unarmoured Cable for Commercial Buildings
Insulation Material |
xlpe |
Application |
Construction, Power Distribution, Home Appliance, Industrial, Underground |
Conductor Material |
Aluminum |
Jacket |
PVC |
Place of Origin |
Henan, China |
Rated Voltage |
0.6 kV, 1 kV |
Brand Name |
JianYun |
Model Number |
YJLV |
Type |
LOW VOLTAGE |
Size |
3*95+1*50 |
Conductor |
Alulminum |
Insulation |
XLPE PE PVC |
Certificate |
ISO9001/CCC |
Core |
3+1 |
Sheath |
PVC Shealth |
Sheating color |
Black |
Voltage |
0.6/1 |
Material |
PVC + Aluminum |
MOQ |
1000 |
Rated voltage |
0.6/1KV |
Construction
Conductor: Aluminium conductor, Class 1: solid conductor, or Class 2: stranded conductor
Insulation:Cross-linked polyethylene XLPE
Filler: Non-hygroscopic material
Binder tape: Non-hygroscopic material
Inner sheath: Polyvinyl chloride PVC
Outer sheath: Polyvinyl chloride PVC
This kind of cable is suitable for industrial facilities with rated voltage 0.6/1kV and power distribution of urban power grid, suitable for laying in underground, underwater, cable pipelines, power stations, outdoor, indoor, industrial and distribution boards, user networks and other places that are not subject to mechanical damage.
0.6/1kV-4+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable |
||||||||
Nominal cross sectional area |
Insulation thickness |
Non-magnetic steel tape thickness |
Sheath thickness |
Approximate outer diameter |
Approx. |
Max.D.C resistance of conductor(20℃) |
Current carrying capacity |
|
weight |
||||||||
mm2 |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
In Air(A) |
In Ground(A) |
4X4+1X2.5 |
0.7/0.7 |
0.2 |
1.8 |
16.3 |
365 |
7.41/12.1 |
- |
30 |
4X6+1X4 |
0.7/0.7 |
0.2 |
1.8 |
17.7 |
429 |
4.61/7.41 |
- |
38 |
4X10+1X6 |
0.7/0.7 |
0.2 |
1.8 |
20.3 |
561 |
3.08/4.61 |
50 |
47 |
4X16+1X10 |
0.7/0.7 |
0.2 |
1.8 |
24 |
728 |
1.91/3.08 |
64 |
62 |
4X25+1X16 |
0.9/0.7 |
0.2 |
1.8 |
28.1 |
974 |
1.2/1.91 |
86 |
78 |
4X35+1X16 |
0.9/0.7 |
0.2 |
1.9 |
29.6 |
1134 |
0.868/1.91 |
105 |
94 |
4X50+1X25 |
1/0.9 |
0.2 |
2 |
34 |
1505 |
0.641/1.2 |
125 |
110 |
4X70+1X35 |
1.1/0.9 |
0.5 |
2.2 |
40.3 |
2351 |
0.443/0.868 |
165 |
135 |
4X95+1X50 |
1.1/1.0 |
0.5 |
2.3 |
44.8 |
2907 |
0.32/0.641 |
200 |
160 |
4X120+1X70 |
1.2/1.1 |
0.5 |
2.6 |
50.2 |
3588 |
0.253/0.443 |
235 |
185 |
4X150+1X70 |
1.4/1.1 |
0.5 |
2.8 |
54.6 |
4215 |
0.206/0.443 |
270 |
205 |
4X185+1X95 |
1.6/1.1 |
0.5 |
2.9 |
60.5 |
5133 |
0.164/0.32 |
310 |
235 |
4X240+1X120 |
1.7/1.2 |
0.5 |
3 |
67.1 |
6289 |
0.125/0.253 |
365 |
260 |
4X300+1X150 |
1.8/1.4 |
0.5 |
3.2 |
73.7 |
7544 |
0.1/0.206 |
420 |
290 |
XLPE insulated power cables for rated voltages of 1 kV (Um = 1,2 kV) is used to
600/1000V XLPE Insulated Cables (IEC 60502-1) are designed for power distributio
The outer PVC (Polyvinyl Chloride) sheath offers additional protection against m
NYY cable, also known as PVC-insulated power cable, is designed for power transm