+86 15290525687 sales@jianyuncable.com
Medium Voltage Power Cable
Medium Voltage Power Cable

Medium voltage (MV) power cables are essential components in modern electrical power distribution systems, designed to handle voltages ranging from 1kV to 35kV. They serve as the backbone for transmitting electrical energy between substations, transformers, and end-user equipment in both industrial and utility settings.

Home / Product / Medium Voltage Power Cable / MV Cross-linked Cable (CU/XLPE/PVC, 1.8-6kV, 95-300mm²)

MV Cross-linked Cable (CU/XLPE/PVC, 1.8-6kV, 95-300mm²)

MV Cross-linked Cable (CU/XLPE/PVC, 1.8-6kV, 95-300mm²)

Medium Voltage 1.8/3kV 3.6/6kV CU/XLPE/PVC 95mm 120mm 150mm 185mm 240mm 300mm Cross-linked Cable

  • Details

Key attributes

Industry-specific attributes

Insulation Material

xlpe

Application

Construction

Conductor Material

Copper

Jacket

PVC

Other attributes

Place of Origin

Henan, China

Brand Name

JianYun

Model Number

YJV- CU/XLPE/PVC

Type

Medium Voltage

Size

3x185mm

Conductor

Copper

Insulation

XLPE

Certificate

ISO9001/CCC

Core

3

Sheath

PVC Shealth

Voltage

1.8/3Kv 3.6/6Kv

Material

XLPE/PVC + copper

Model Number

YJV- CU/XLPE/PVC

Application

construction

Color

Black

PRODUCT DETAIL

1.8/3kV 3.6/6kV Copper Conductor XLPE Insulation PVC Sheath 3 Core Unarmoured Cable

Construction

Conductor : Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2.


Conductor Screen : The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape. The conductor screen is applied under triple extrusion process over the conductor along with the insulation and the insulation screen. The extruded semi-conducting compound is firmly bonded to the insulation to exclude all air voids and can be easily hand stripped on site. The conductor screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3.6KV and 3.6/6KV cables.


Insulation : Insulation is of polyvinyl chloride (PVC) intended for 1.8/3.6KV and 3.6/6KV cables, cross-linked polyethylene
compound (XLPE) or ethylene propylene rubber (EPR/HEPR).

 

Insulaton Screen : The insulation screen consists of an extruded layer of non metallic, semi-conducting compound extruded over the insulation of each core. The insulation screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3.6KV and 3.6/6KV cables. The screen may be covered by semi-conductive water blocking swellable tape to ensure longitudinal watertightness. 

Inner Covering & Fillers : For cables with a collective metallic layer or cables with a metallic layer over each individual cores with additional collective metallic layers, semi-conducting inner covering and fillers shall be applied over the laid up cores.The inner covering and fillers are made of non hygroscopic material like polypropylene, except if the cable is to be made longitudinally watertight. The inner covering is extruded in general but may be lapped if the interstices between the cores are filled.

Application

The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.


Standards
IEC 60502 Part 1(1.8/3KV)
IEC 60502 Part 2(3.6/6KV to 18/30KV)

Product Paramenters

Three Core 1.8/3KV (Um=3.6KV)

Nom. Cross- Section Area

Nom. Insulation Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

CU

AL

mm2

mm

mm

mm

kg/km

10

2

1.8

23

650

460

16

2

1.8

24

840

540

25

2

1.8

26

1160

680

35

2

1.8

29

1490

820

50

2

1.9

32

1900

1000

70

2

2

36

2580

1290

95

2

2.2

40

3440

1640

120

2

2.3

43

4220

1950

150

2

2.4

46

5090

2290

185

2

2.5

50

6240

2730

240

2

2.7

56

8030

3430

300

2

2.8

60

9890

4100

400

2

3.1

68

12530

5150

500

2.2

3.3

75.7

16680

7510

630

2.4

3.5

84.9

21770

10040

Three Core 3.6/6KV (Um=7.2KV)

Nom. Cross- Section Area

Nom. Insulation Thickness

Copper Tape Screen Area (0.1mm)

Copper Wire Screen Area

Nom. Sheath Thickness

Approx. Overall Diameter

Approx.Weight

CU

AL

mm2

mm

mm2

mm2

mm

mm

kg/km

10

2.5

4.2

16

2

30

980

790

16

2.5

4.6

16

2

31

1190

890

25

2.5

5

16

2.1

34

1560

1080

35

2.5

5.4

16

2.2

37

1930

1270

50

2.5

5.9

16

2.3

40

2370

1480

70

2.5

6.6

16

2.4

43

3110

1820

95

2.5

7.3

16

2.5

47

4000

2200

120

2.5

8

16

2.6

50

4820

2550

150

2.5

8.5

25

2.8

54

5770

2970

185

2.5

9.4

25

2.9

58

6960

3460

240

2.6

10.4

25

3.1

65

8940

4340

300

2.8

11.4

25

3.3

70

10980

5190

400

3

12.6

35

3.5

79

13820

6440

500

3.2

13.9

35

3.7

87

19100

10755

630

3.2

15.3

35

4

95

30470

13150

 


Related Products